- Films
Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
- Sheets
Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials
Accurate Data
- Brand new dome design test chamber and 360o air circulation constant temperature technology ensures better temperature stability.
- Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01~0.09cm3/ m3·24h·0.1MPa test range.
- Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
- Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
- The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
- Labthink's unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
- The pressure in high-pressure chamber can be set within the range of 10kPa~210kPa, the pressure can be maintained accurately and stably by the system.
High Efficiency
- Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
- Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
- Medium and low barrier materials, test time
- High barrier materials, test time
- Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.
Intelligent control
- 12" touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
- Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
- Intelligent test chamber hood automatically opens and closes with sound and light alert.
Safe and reliable
- System security - Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
- Operation safety - Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
- Performance reliability - the instrument adopts components of global renowned brands, to ensure stable and reliable performance.
Space saving
- The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.
Powerful functions
- Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
- The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
- Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
- Ultra-wide test range to meet the barrier test of various materials (customize).
- Tests of hazardous gases such as H2、CH4 are applicable (Customize).
ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003
Test Parameters
Parameters/Model |
C106H |
Test range |
cm3/m2·24h·0.1MPa |
0.01~50,000 |
Resolution |
cm3/m2·24h·0.1MPa |
0.001 |
Test temperature |
oC |
15~50, 5~60(Optional) |
Temperature resolution |
oC |
0.01 |
Temperature fluctuation |
oC |
±0.15 |
Test humidity |
%RH(Within standard test temperature range) |
0%, 5~90%±2%(Customize) |
Vacuum Resolution |
Pa |
0.01 |
Vacuum Accuracy |
Pa |
±0.2%(1%-100% of Full Scale) |
Vacuum Degree of Test Chamber |
Pa |
<= 10 |
Additional Functions |
DataShieldTM note3 |
Optional |
GMP Computer System requirement |
Optional |
CFR21Part11 |
Optional |
Technical Specifications
Test Cell |
6 Cells |
Specimen Size |
4.6" x 4.6"(11.7cm×11.7cm) |
Specimen Thickness |
<=120 Mil(3mm) |
Standard test area |
38.48cm2 |
Test Gas |
O2、N2、CO2 etc.(Outside of supply scope) |
Test Pressure |
10 kPa~210 kPa(Can be set between) |
Pressure Fluctuation |
0.2 kPa |
Gas Pressure |
79.7 PSI / 550 kPa |
Port Size |
Φ6 mm PU tubing |
Instrument Dimension |
23.6" H x 19.2" W x 25.9" D (60cm x 49cm x 66cm) |
Power Supply |
120VAC±10% 60Hz/220VAC±10% 50Hz(one of two) |
Net Weight |
220Lbs(100kg) |
Product Configuration
Standard Configuration |
Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, Φ6 mm PU tubing |
Optional Parts |
Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3 |
Note |
The gas compressor port of the instrument is Φ6 mm PU tubing(pressure >= 79.7 PSI/ 550kPa), customers need to prepare gas supply. |
Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.